Column - multiple species

Column - multiple species, Profile - multiple species FTIR Spectrometer (Bruker 120HR/125) at Kiruna, Sweden

Site (station location)
Kiruna, Sweden
Instrument Type
FTIR Spectrometer
Model
Bruker 120HR/125
Instrument Status
Active
Periods of Activity
1996
–present
Cooperating Institutions
IMK-ASF
IRF
STEL
M&A Directory Entry

T. Blumenstock (IMK-ASF), U. Raffalski (IRF), and Y. Matsumi (STEL) — Bruker 120HR (0.002 cm 1 resolution) operated since 1996. It is fitted with four detectors for both solar and lunar measurements. Intercompared with the NPL travel instrument in March 1998. Remote control capability exists since 2004. Upgraded to Bruker 125 in 2007.

Column - multiple species FTIR Spectrometer () at Polarstern, Germany (Ship-Based)

Site (station location)
Polarstern, Germany (Ship-Based)
Instrument Type
FTIR Spectrometer
Instrument Status
Campaign
Periods of Activity
1996
1999
–2000
2002
–2003
Cooperating Institutions
AWI, Germany
U. Bremen
M&A Directory Entry

O. Schrems (AWI) and J. Notholt (U. Bremen) – Bruker 120M (0.004 cm-1 resolution), deployed 1992 to 1995 at Ny Ålesund (78.92ºN, 11.93ºE) and now utilized as a mobile instrument. Operated as part of the ALBATROSS ship-based expedition from 70ºN to 40ºS during October and November 1996.  Participated in additional ship-based expeditions in 1999/2000 (from 80ºN to 70ºS), in June 2000, November 2002, January/February 2003, October/November 2003, and October/November 2005.

Column - multiple species FTIR Spectrometer (Bruker 120M) at Eureka, Canada

Site (station location)
Eureka, Canada
Instrument Type
FTIR Spectrometer
Model
Bruker 120M
Instrument Status
Campaign
Cooperating Institutions
NPL
M&A Directory Entry

P. Woods, B. Bell, C. Paton-Walsh, and T. Gardiner (NPL) – Bruker 120M (0.004 cm-1 resolution) used for intercomparisons and campaigns (see subsequent entries). Measurements in Eureka were made in May 1999 but the data are not in the NDACC archive.

Column - multiple species FTIR Spectrometer (Bruker 120M) at Table Mountain Facility, CA, United States

Site (station location)
Table Mountain Facility, CA, United States
Instrument Type
FTIR Spectrometer
Model
Bruker 120M
Instrument Status
Campaign
Cooperating Institutions
NPL
M&A Directory Entry

P. Woods, B. Bell, C. Paton-Walsh, and T. Gardiner (NPL) – Bruker 120M (0.004 cm-1 resolution) used for intercomparisons and campaigns.  Measurements were made in October 1996.  However, this data has not been archived.

Column - multiple species FTIR Spectrometer (Bruker 120M) at Lauder, New Zealand

Site (station location)
Lauder, New Zealand
Instrument Type
FTIR Spectrometer
Model
Bruker 120M
Instrument Status
Campaign
Cooperating Institutions
NPL
M&A Directory Entry

P. Woods, B. Bell, C. Paton-Walsh, and T. Gardiner (NPL) – Bruker 120M (0.004 cm-1 resolution) used for intercomparisons and campaigns.  Measurements were made in February 1997 but have not been archived.

Column - multiple species FTIR Spectrometer (Bruker 120M) at Jungfraujoch, Switzerland

Site (station location)
Jungfraujoch, Switzerland
Instrument Type
FTIR Spectrometer
Model
Bruker 120M
Instrument Status
Campaign
Periods of Activity
1992
Cooperating Institutions
NPL
M&A Directory Entry

P. Woods, B. Bell, C. Paton-Walsh, and T. Gardiner (NPL) – Bruker 120M (0.004 cm-1 resolution) used for intercomparisons and campaigns.  Measurements were made in October 1992.

Comments
*.wof

Column - multiple species FTIR Spectrometer (Bruker 120M) at Aberdeen, United Kingdom

Site (station location)
Aberdeen, United Kingdom
Instrument Type
FTIR Spectrometer
Model
Bruker 120M
Instrument Status
Campaign
Periods of Activity
1994
–1995
Cooperating Institutions
NPL
M&A Directory Entry

P. Woods, B. Bell, C. Paton-Walsh, and T. Gardiner (NPL) – Bruker 120M (0.004 cm-1 resolution) used for intercomparisons and campaigns.  Measurements were made during SESAME I for January to May 1994 and SESAME II for November 1994 to April 1995.

Comments
*.wof

Column - multiple species FTIR Spectrometer (Bruker 120M) at Harestua, Norway

Site (station location)
Harestua, Norway
Instrument Type
FTIR Spectrometer
Model
Bruker 120M
Instrument Status
Campaign
Periods of Activity
1994
Cooperating Institutions
NPL
M&A Directory Entry

P. Woods, B. Bell, C. Paton-Walsh, and T. Gardiner (NPL) – Bruker 120M (0.004 cm-1 resolution) used for intercomparisons and campaigns.  Measurements were made from September–October 1994.

Comments
*.wof

Column - multiple species FTIR Spectrometer (EOCOM) at Søndre Strømfjord, Greenland

Site (station location)
Søndre Strømfjord, Greenland
Instrument Type
FTIR Spectrometer
Model
EOCOM
Instrument Status
Campaign
Periods of Activity
1994
–1995
Cooperating Institutions
NCAR
M&A Directory Entry

J. Hannigan, M. Coffey, and W. Mankin (NCAR) – SESAME Campaign data have been archived for the period October 1994 to March 1995.

Column - multiple species FTIR Spectrometer (JPL MkIV) at Mt. Barcroft, CA, United States

Site (station location)
Mt. Barcroft, CA, United States
Instrument Type
FTIR Spectrometer
Model
JPL MkIV
Instrument Status
Campaign
Periods of Activity
1985
–present
Cooperating Institutions
JPL
M&A Directory Entry

G. C. Toon (JPL) — Intermittent operation of a home-built interferometer (JPL MkIV with 0.006 cm 1 resolution) from August 1994 to July 2002. This instrument was also launched on a balloon periodically between October 1989 and 2014. A database of MkIV column abundances from twelve different sites covering 1985–2015 is in the archive. Sites include Mt. Barcroft, JPL (Pasadena, CA; 34.20˚N, 118.17˚W), Table Mountain Observatory, McMurdo Antarctica, and Ft. Sumner New Mexico.